Booster Septum Magnets
Drawings
Injector Synchrotron - Injection
Septum Magnet Final Assembly
****A129600 - Injection Synchrotron -
Injection Septum Magnet Core Sub-Assembly
Injector Synchrotron - Injection
Septum Magnet Core Sub-Assembly Coil Bar
****A2431600 - Injection Synchrotron AC Thin Extraction
Magnet General Assembly
**** A0964601 - Injection Synchrotron AC Thick Extraction
Magnet Assembly
Injection Synchrotron AC Thick
Extraction Magnet Coil Assembly
Injector Synchrotron AC Thick
Extraction Magnet Coil Assembly Copper Conductor
Tables
Synchrotron Injection Thin Septum
Operational Parameters
Synchrotron Extraction Thin Septum
Operational Parameters
Synchrotron Thick Extraction Septum
Operational Parameters
Synchrotron
Injection Thin Septum
( 22104 - 700000 )
Operational Parameters*
Number | 1 |
Minimum Septum Thickness | 2.0 mm |
Physical Length | 0.9 m |
Effective Length | 0.8 m |
Bending Angle | 0.2718 rad |
Peak Field at 450 MeV | 0.51 T |
Gap Height | 30 mm |
*data from H.B. 7/96-- to be updated by S.M.
Synchrotron
Extraction Thin Septum
( 22106 - 200000 )
Operational Parameters*
Number | 1 |
Minimum Septum Thickness | 2.0 mm |
Physical Length | 1.06 m |
Effective Length | 1.05 m |
Bending Angle | 32.76 mrad |
Peak Field at 450 MeV | 0.73 T |
Maximum Field | 0.8 T |
Gap Height | 20 mm |
Gap Width | 34 mm |
*data from H.B. 7/96-- to be updated by S.M.
Synchrotron Thick
Extraction Septum
( 220107-700000 )
Operational Parameters*
Number | |
Minumum Septum Thickness | 30 mm |
Physical Length | 1.79 m |
Effective Length | 1.75 m |
Bending Angle | 73.53 mrad |
Peak Field at 7 GeV | 0.98 T |
Maximum Field | 1.1 T |
Gap Height | 30 mm |
Gap Width | 40 mm |
*data from H.B. 7/97-- to be updated by S.M.