Booster Septum Magnets

Drawings

Injector Synchrotron - Injection Septum Magnet Final Assembly
****A129600 - Injection Synchrotron - Injection Septum Magnet Core Sub-Assembly
Injector Synchrotron - Injection Septum Magnet Core Sub-Assembly Coil Bar

****A2431600 - Injection Synchrotron AC Thin Extraction Magnet General Assembly
**** A0964601 - Injection Synchrotron AC Thick Extraction Magnet Assembly

Injection Synchrotron AC Thick Extraction Magnet Coil Assembly
Injector Synchrotron AC Thick Extraction Magnet Coil Assembly Copper Conductor

Tables

Synchrotron Injection Thin Septum Operational Parameters
Synchrotron Extraction Thin Septum Operational Parameters
Synchrotron Thick Extraction Septum Operational Parameters


Synchrotron Injection Thin Septum
( 22104 - 700000 )
Operational Parameters*

Number 1
Minimum Septum Thickness 2.0 mm
Physical Length 0.9 m
Effective Length 0.8 m
Bending Angle 0.2718 rad
Peak Field at 450 MeV 0.51 T
Gap Height 30 mm

*data from H.B. 7/96-- to be updated by S.M.


Synchrotron Extraction Thin Septum
( 22106 - 200000 )
Operational Parameters*

Number 1
Minimum Septum Thickness 2.0 mm
Physical Length 1.06 m
Effective Length 1.05 m
Bending Angle 32.76 mrad
Peak Field at 450 MeV 0.73 T
Maximum Field 0.8 T
Gap Height 20 mm
Gap Width 34 mm

*data from H.B. 7/96-- to be updated by S.M.


Synchrotron Thick Extraction Septum
( 220107-700000 )
Operational Parameters*

Number
Minumum Septum Thickness 30 mm
Physical Length 1.79 m
Effective Length 1.75 m
Bending Angle 73.53 mrad
Peak Field at 7 GeV 0.98 T
Maximum Field 1.1 T
Gap Height 30 mm
Gap Width 40 mm