The first section of the 450-MeV positron beam transport line from the positron linac to the PAR contains 10 quadrupoles and one bending dipole.

Parameters of the low energy transport line between linac and PAR are given below.

2.2.1        Magnets

Dipoles
  Number 1
  Magnetic Length 0.4 m
  Bending Angle 0.2 rad
  Field 0.75 T
Quadrupoles
  Number 10
  No. of independent power supplies 10
  Magnetic Length 0.3 m
  Max gradient 12.7 T / m
  Pole tip inscribed radius 32 mm

2.2.2        Beam Diagnostics (number of each type)

Current monitor 1
Position monitors 4  per plane
Loss monitor 1
Fluorescent screens 3

                LTP parameters for beam diagnostics

Peak Current (linac output) 8 mA
Bunch length (from linac) 30 ns
Intensity per pulse 1.5 x 109 e+
Charge per pulse 240 pC
Number of pulses 24
Pulse repetition rate 60 Hz

2.4           PTB (PAR to Booster) Transport Line

The second section of the 450-MeV positron beam transport line from the PAR to the injector synchrotron (also known as booster) contrains 11 quadrupoles and two horizontal bends.  The two bends in opposite polarities form an achromatic horizontal parallel translation together with four quadrupoles.

Parameters of the low energy transport line from PAR to injector synchrotron (or booster) are given below.

2.4.1        Magnets

Dipoles
  Number 2
  No. of independent power supplies 2
  Magnetic Length 0.4 m
  Bending angle 0.2 rad
  Field 0.75 T
  Bending angle 0.187 rad
  Field 0.703 T
Quadrupoles
  Number 11
  No. of independent power supplies 11
     Magnetic length 0.3 m
     Max gradient 12.7 T / m
  Pole tip inscribed radius 32 mm

2.4.2        Beam Diagnostics (number of each type)

Current monitor 1
Position monitors 5  per plane
Loss monitor 1
Fluorescent screens 3

                 PTB parameters for beam diagnostics

Peak current (assume Gaussian bunch) 7.92 A
Bunch length (from the PAR) 0.29 ns
Intensity per bunch, at 100% efficiency 3.6 x 1010 e+
Charge per pulse, at 100% efficiency 5.76 nC
Pulse repetition rate 2 Hz