LET Magnets
Drawings
Tables
LTP (Linac to PAR) Transport
Line
PTB (PAR to Booster) Transport Line
2.2 LTP (Linac to PAR) Transport Line
The first section of the 450-MeV positron beam transport line from the positron linac to the PAR contains 10 quadrupoles and one bending dipole.
Parameters of the low energy transport line between linac and PAR are given below.
2.2.1 Magnets
Dipoles | ||
Number | 1 | |
Magnetic Length | 0.4 | m |
Bending Angle | 0.2 | rad |
Field | 0.75 | T |
Quadrupoles | ||
Number | 10 | |
No. of independent power supplies | 10 | |
Magnetic Length | 0.3 | m |
Max gradient | 12.7 | T / m |
Pole tip inscribed radius | 32 | mm |
2.2.2 Beam Diagnostics (number of each type)
Current monitor | 1 |
Position monitors | 4 per plane |
Loss monitor | 1 |
Fluorescent screens | 3 |
LTP parameters for beam diagnostics
Peak Current (linac output) | 8 | mA |
Bunch length (from linac) | 30 | ns |
Intensity per pulse | 1.5 x 109 | e+ |
Charge per pulse | 240 | pC |
Number of pulses | 24 | |
Pulse repetition rate | 60 | Hz |
2.4 PTB (PAR to Booster) Transport Line
The second section of the 450-MeV positron beam transport line from the PAR to the injector synchrotron (also known as booster) contrains 11 quadrupoles and two horizontal bends. The two bends in opposite polarities form an achromatic horizontal parallel translation together with four quadrupoles.
Parameters of the low energy transport line from PAR to injector synchrotron (or booster) are given below.
2.4.1 Magnets
Dipoles | ||
Number | 2 | |
No. of independent power supplies | 2 | |
Magnetic Length | 0.4 | m |
Bending angle | 0.2 | rad |
Field | 0.75 | T |
Bending angle | 0.187 | rad |
Field | 0.703 | T |
Quadrupoles | ||
Number | 11 | |
No. of independent power supplies | 11 | |
Magnetic length | 0.3 | m |
Max gradient | 12.7 | T / m |
Pole tip inscribed radius | 32 | mm |
2.4.2 Beam Diagnostics (number of each type)
Current monitor | 1 |
Position monitors | 5 per plane |
Loss monitor | 1 |
Fluorescent screens | 3 |
PTB parameters for beam diagnostics
Peak current (assume Gaussian bunch) | 7.92 | A |
Bunch length (from the PAR) | 0.29 | ns |
Intensity per bunch, at 100% efficiency | 3.6 x 1010 | e+ |
Charge per pulse, at 100% efficiency | 5.76 | nC |