Abstract:

This paper will discuss the survey and adjustment of the Fermilab Main Injector transport line. The main concerns of this paper deal with the design of the control network, selection of instrumentation, the methods of measurement and reduction used to meet the accuracy specifications needed to position the machine components and monitoring devices. The paper will analyze the accuracy of the results achieved through the combination of measuring with the SMX Laser Tracker, the Kern ME5000, the Kern E2 and the Leica NA3000.